Levelized Cost of Electricity Calculator

LCOE spreads a generation project’s capital cost over its economic life using an explicit discount rate. The annualized capital amount plus annual operating cost is divided by annual generation. At a zero discount rate, capital recovery becomes cost divided by years, which avoids a division-by-zero formula at that boundary.

Your inputs

currency
kWh/year
currency/year
years
%

Example inputs are editable. Use your own equipment data and current tariff. Prices use one consistent currency: enter 20 cents or pence as 0.20.

Your result

Awaiting your inputs

Enter your values and press Calculate. Your result will appear here.

Clear units · Editable assumptions · Published formula sources

The method

Formula and calculation steps

CRF = r(1+r)^n/[(1+r)^n−1], or 1/n at r=0; LCOE = (capital×CRF + annual O&M)/annual kWh.

Calculate a simplified annualized generation cost per kWh with a capital recovery factor.

  1. Identify the quantities and units required by the form.
  2. Use measurements, a current bill or relevant equipment data for the same period.
  3. Apply the displayed formula, then check the assumptions and related outputs.

This fixed-output model excludes fuel, degradation, replacement, taxes, salvage and financing structure. Use consistent real or nominal money assumptions.

Levelized energy cost versus a household electricity tariff

LCOE spreads a generation project’s capital cost over its economic life using an explicit discount rate. The annualized capital amount plus annual operating cost is divided by annual generation. At a zero discount rate, capital recovery becomes cost divided by years, which avoids a division-by-zero formula at that boundary.

A solar cost per kWh result is not the same as an export payment or retail tariff. LCOE describes the specified generation cost boundary; its value does not include when the energy is useful. Compare projects using consistent annual output, operating costs and discount conventions rather than comparing one full-system cost with another partial component.

Check the numbers

Levelized Cost of Electricity Calculator: calculated examples

Compare stated scenarios rather than an unexplained rule of thumb. Each row uses the same calculation function as the form.

Worked example with the starting inputs

Installed capital cost: 10,000 currency; Constant annual generation: 6,000 kWh/year; Annual operations and maintenance: 100 currency/year; Economic lifetime: 25 years; Discount rate: 5 %. Simplified LCOE: 0.134921 currency/kWh.

OutputComputed value
Simplified LCOE0.134921 currency/kWh
Capital recovery factor0.070952 per year
Annualized capital709.524573 currency/year

How the answer changes

ScenarioChanged inputResult
2,500 currencyInstalled capital cost: 2,500 currency0.04623 currency/kWh
5,000 currencyInstalled capital cost: 5,000 currency0.075794 currency/kWh
7,500 currencyInstalled capital cost: 7,500 currency0.105357 currency/kWh
10,000 currencyInstalled capital cost: 10,000 currency0.134921 currency/kWh
15,000 currencyInstalled capital cost: 15,000 currency0.194048 currency/kWh
20,000 currencyInstalled capital cost: 20,000 currency0.253175 currency/kWh
30,000 currencyInstalled capital cost: 30,000 currency0.371429 currency/kWh

All inputs not changed in a row use: Installed capital cost = 10,000 currency; Constant annual generation = 6,000 kWh/year; Annual operations and maintenance = 100 currency/year; Economic lifetime = 25 years; Discount rate = 5 %. These are chosen examples, not current rates or product performance claims.

Common questions

What is the levelized cost of electricity formula?

This simplified capital-recovery version divides annualized capital plus annual O&M by constant annual energy.

What happens when the discount rate is zero?

The annual capital recovery factor is 1 divided by economic lifetime.

Does this include battery replacements?

No. Replacement cash flows and changing production need a fuller lifetime model.

Can I use it for coal or diesel generation?

Not as a complete cost. Fuel and other omitted costs must be modeled separately; the current inputs alone are insufficient.

Does a low LCOE guarantee bill savings?

No. Export value, self-consumption, demand timing and remaining tariff fees determine the bill impact.

Which inputs should I verify before using this result?

Check the units, dates and measurement boundary shown above. The examples are deliberately chosen scenarios rather than current tariffs, certified product ratings or promises about a particular installation.

Where do the formulas and example values come from?

The method is explained on this page and the published references are listed below as plain-text addresses. Example inputs are illustrative; comparison rows are computed with the same calculation function as the form.

Formula sources and references

These references support the units and underlying methods. Defaults and comparison cases are illustrative inputs, not current tariffs or product test data.

  • NLR: Simple Levelized Cost of Energy Calculator documentationhttps://www.nlr.gov/analysis/tech-lcoe