Electricity Costby Voltage Drop Calculator

Electricity calculators / Gas, carbon & business

Know your usage. Understand your bill.

Gas vs Electric Heating Cost Calculator

A gas versus electricity comparison must include how much useful heat reaches the space or water. The price per therm, gallon or kWh cannot be compared directly without energy content and appliance efficiency. Enter the fuel energy per purchased unit using the supplier’s convention, and retain the same unit in its price.

Your inputs

kWh thermal
kWh/fuel unit
currency/fuel unit
%
currency/kWh
heat kWh/electric kWh

Example inputs are editable. Use your own equipment data and current tariff. Prices use one consistent currency: enter 20 cents or pence as 0.20.

Your result

Awaiting your inputs

Enter your values and press Calculate. Your result will appear here.

Clear units · Editable assumptions · Published formula sources

The method

Formula and calculation steps

Fuel cost = useful heat÷fuel efficiency÷fuel kWh per unit×fuel price; electric cost = useful heat÷COP×electricity rate.

Compare gas, propane or other purchased fuel with electric heating on an equal useful-heat basis.

  1. Identify the quantities and units required by the form.
  2. Use measurements, a current bill or relevant equipment data for the same period.
  3. Apply the displayed formula, then check the assumptions and related outputs.

Fuel content, efficiency and COP must use compatible assumptions. There are no current fuel prices, automatic weather effects or installation costs.

Propane, gas and electric heating on a common heat basis

A gas versus electricity comparison must include how much useful heat reaches the space or water. The price per therm, gallon or kWh cannot be compared directly without energy content and appliance efficiency. Enter the fuel energy per purchased unit using the supplier’s convention, and retain the same unit in its price.

For resistive electric heat, a COP of one represents the ideal electrical-input-to-heat relationship at that boundary. For a heat pump, use a measured or credible seasonal COP rather than assuming a constant advertised best point applies all winter. This calculation compares operating energy costs only and does not specify a heating system for a building.

Check the numbers

Gas vs Electric Heating Cost Calculator: calculated examples

Compare stated scenarios rather than an unexplained rule of thumb. Each row uses the same calculation function as the form.

Worked example with the starting inputs

Required useful heat: 1,000 kWh thermal; Fuel energy per purchased unit: 29.307107 kWh/fuel unit; Price per fuel unit: 2 currency/fuel unit; Fuel appliance seasonal efficiency: 85 %; Electricity unit rate: 0.2 currency/kWh; Electric system effective COP: 1 heat kWh/electric kWh. Electric-system savings versus fuel: -119.714314 currency.

OutputComputed value
Electric-system savings versus fuel-119.714314 currency
Fuel-system variable cost80.285686 currency
Electric-system variable cost200 currency
Purchased electricity1,000 kWh

How the answer changes

ScenarioChanged inputResult
0.05 currency/kWhElectricity unit rate: 0.05 currency/kWh30.285686 currency
0.1 currency/kWhElectricity unit rate: 0.1 currency/kWh-19.714314 currency
0.15 currency/kWhElectricity unit rate: 0.15 currency/kWh-69.714314 currency
0.2 currency/kWhElectricity unit rate: 0.2 currency/kWh-119.714314 currency
0.3 currency/kWhElectricity unit rate: 0.3 currency/kWh-219.714314 currency
0.4 currency/kWhElectricity unit rate: 0.4 currency/kWh-319.714314 currency
0.6 currency/kWhElectricity unit rate: 0.6 currency/kWh-519.714314 currency

All inputs not changed in a row use: Required useful heat = 1,000 kWh thermal; Fuel energy per purchased unit = 29.307107 kWh/fuel unit; Price per fuel unit = 2 currency/fuel unit; Fuel appliance seasonal efficiency = 85 %; Electricity unit rate = 0.2 currency/kWh; Electric system effective COP = 1 heat kWh/electric kWh. These are chosen examples, not current rates or product performance claims.

Common questions

Can I compare propane with electricity?

Yes. Enter propane energy per purchased unit and the price for that same unit, plus the actual heating-system efficiency.

Is a therm always the same?

Different therm conventions exist. This default illustrates an EC/IT therm; use the basis stated by the fuel supplier.

Does a heat pump have 300% electrical efficiency?

A COP of three means three heat units delivered per electric unit at the chosen boundary. It transfers heat, so COP is different from a combustion efficiency.

Does this predict seasonal COP?

No. COP is an input. Weather, flow temperatures and equipment behavior must be assessed separately.

Does it include gas standing charges?

No. It compares variable purchased energy costs. Fixed fees matter if changing systems would actually avoid them.

Which inputs should I verify before using this result?

Check the units, dates and measurement boundary shown above. The examples are deliberately chosen scenarios rather than current tariffs, certified product ratings or promises about a particular installation.

Where do the formulas and example values come from?

The method is explained on this page and the published references are listed below as plain-text addresses. Example inputs are illustrative; comparison rows are computed with the same calculation function as the form.

Formula sources and references

These references support the units and underlying methods. Defaults and comparison cases are illustrative inputs, not current tariffs or product test data.

  • NIST SP 811, Appendix B: SI and non-SI conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors
  • NIST SP 811 footnotes: International Table Btu and therm conventionshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-footnotes
  • US EIA: Measuring electricity; power and energy unitshttps://www.eia.gov/energyexplained/electricity/measuring-electricity.php