Electricity calculators / Gas, carbon & business
Know your usage. Understand your bill.
Electricity Demand Charge Calculator
Commercial bills can charge for the maximum relevant interval demand as well as total energy. Reducing monthly kWh does not necessarily reduce the billed peak if a short high-load event remains. The demand rate must correspond to the same period as the fixed and energy amounts.
Your inputs
Your result
Awaiting your inputsEnter your values and press Calculate. Your result will appear here.
Clear units · Editable assumptions · Published formula sources
The method
Formula and calculation steps
Total = billed peak kW×demand rate + period kWh×energy rate + fixed period charge.
Separate demand, energy and fixed components of a commercial electricity bill.
- Identify the quantities and units required by the form.
- Use measurements, a current bill or relevant equipment data for the same period.
- Apply the displayed formula, then check the assumptions and related outputs.
Enter demand established under the tariff. Ratchets, minimum billed demand, kVA penalties and contracted-capacity rules are not inferred from kWh.
Industrial and small-business demand charges
Commercial bills can charge for the maximum relevant interval demand as well as total energy. Reducing monthly kWh does not necessarily reduce the billed peak if a short high-load event remains. The demand rate must correspond to the same period as the fixed and energy amounts.
Use the actual tariff’s billed demand rather than estimating it from monthly energy alone. Some schedules use a demand ratchet, minimum or kVA instead of measured real kW; those require specific rules outside this form. This calculator is an explicit three-component example rather than an official industrial billing system.
Continue with: Gas Meter to kWh Calculator · kWh to Gas Volume Calculator · Gas vs Electric Heating Cost Calculator · Electricity Carbon Emissions Calculator
Check the numbers
Electricity Demand Charge Calculator: calculated examples
Compare stated scenarios rather than an unexplained rule of thumb. Each row uses the same calculation function as the form.
Worked example with the starting inputs
Billed peak demand: 20 kW; Demand charge rate: 15 currency/kW/period; Energy used: 300 kWh; Electricity unit rate: 0.2 currency/kWh; Fixed charge for the period: 10 currency. Three-component bill: 370 currency.
| Output | Computed value |
|---|---|
| Three-component bill | 370 currency |
| Demand charge | 300 currency |
| Energy charge | 60 currency |
| Fixed charge | 10 currency |
How the answer changes
| Scenario | Changed input | Result |
|---|---|---|
| 5 kW | Billed peak demand: 5 kW | 145 currency |
| 10 kW | Billed peak demand: 10 kW | 220 currency |
| 15 kW | Billed peak demand: 15 kW | 295 currency |
| 20 kW | Billed peak demand: 20 kW | 370 currency |
| 30 kW | Billed peak demand: 30 kW | 520 currency |
| 40 kW | Billed peak demand: 40 kW | 670 currency |
| 60 kW | Billed peak demand: 60 kW | 970 currency |
All inputs not changed in a row use: Billed peak demand = 20 kW; Demand charge rate = 15 currency/kW/period; Energy used = 300 kWh; Electricity unit rate = 0.2 currency/kWh; Fixed charge for the period = 10 currency. These are chosen examples, not current rates or product performance claims.
Common questions
Can I calculate maximum demand from kWh?
Not from a total alone. Matching interval energy can establish interval-average demand, and its maximum is then evaluated under the tariff.
Are demand kW and energy kWh charged the same way?
No. One prices the relevant power peak and the other prices accumulated energy.
Can I enter a kVA demand tariff?
This page is labeled for kW demand. Convert only with an appropriate tariff and power-factor basis, or use an applicable utility calculator.
What is a ratchet?
A tariff can retain a billing minimum related to earlier demand. This tool does not calculate that historical rule.
Does lowering use always reduce the demand fee?
No. The peak billing interval may remain unchanged even if many other hours use less electricity.
Which inputs should I verify before using this result?
Check the units, dates and measurement boundary shown above. The examples are deliberately chosen scenarios rather than current tariffs, certified product ratings or promises about a particular installation.
Where do the formulas and example values come from?
The method is explained on this page and the published references are listed below as plain-text addresses. Example inputs are illustrative; comparison rows are computed with the same calculation function as the form.
Related calculators
Formula sources and references
These references support the units and underlying methods. Defaults and comparison cases are illustrative inputs, not current tariffs or product test data.
- US EIA: Measuring electricity; power and energy unitshttps://www.eia.gov/energyexplained/electricity/measuring-electricity.php
- US Department of Energy: Fundamentals Handbook, Electrical Science, Volume 3, AC powerhttps://www.energy.gov/sites/default/files/2026-04/DOE-HDBK-1011-92_VOL3.pdf