Energy Use Intensity Calculator

Energy use intensity divides a clearly defined energy total by the corresponding building area. State whether the area includes garages, shared spaces or conditioned area, and use the same definition across comparisons. A small office and a continuously occupied server facility should not be judged using one unqualified average.

Your inputs

kWh/year
m²

Example inputs are editable. Use your own equipment data and current tariff. Prices use one consistent currency: enter 20 cents or pence as 0.20.

Your result

Awaiting your inputs

Enter your values and press Calculate. Your result will appear here.

Clear units · Editable assumptions · Published formula sources

The method

Formula and calculation steps

Electricity intensity = annual kWh/floor area m²; IT kBtu/ft² = kWh/m²×3.412141633/10.763910417.

Calculate electricity-only energy use per floor area in kWh/m²/year and kBtu/ft²/year.

  1. Identify the quantities and units required by the form.
  2. Use measurements, a current bill or relevant equipment data for the same period.
  3. Apply the displayed formula, then check the assumptions and related outputs.

This is electricity-only site intensity, not a whole-building energy benchmark, source EUI or climate-normalized score. Fuel energy is not included.

Energy cost index, building energy and floor area

Energy use intensity divides a clearly defined energy total by the corresponding building area. State whether the area includes garages, shared spaces or conditioned area, and use the same definition across comparisons. A small office and a continuously occupied server facility should not be judged using one unqualified average.

An energy cost index would also require prices and a matching cost boundary. This page calculates electricity intensity only. It does not assign a rating, normalize weather or claim that an electricity-only result represents total site energy where gas or other fuels are also consumed.

Check the numbers

Energy Use Intensity Calculator: calculated examples

Compare stated scenarios rather than an unexplained rule of thumb. Each row uses the same calculation function as the form.

Worked example with the starting inputs

Annual site electricity: 12,000 kWh/year; Floor area: 100 m². Electricity-only site intensity: 120 kWh/m²/year.

OutputComputed value
Electricity-only site intensity120 kWh/m²/year
Same electricity intensity38.0398 kBtu/ft²/year

How the answer changes

ScenarioChanged inputResult
3,000 kWh/yearAnnual site electricity: 3,000 kWh/year30 kWh/m²/year
6,000 kWh/yearAnnual site electricity: 6,000 kWh/year60 kWh/m²/year
9,000 kWh/yearAnnual site electricity: 9,000 kWh/year90 kWh/m²/year
12,000 kWh/yearAnnual site electricity: 12,000 kWh/year120 kWh/m²/year
18,000 kWh/yearAnnual site electricity: 18,000 kWh/year180 kWh/m²/year
24,000 kWh/yearAnnual site electricity: 24,000 kWh/year240 kWh/m²/year
36,000 kWh/yearAnnual site electricity: 36,000 kWh/year360 kWh/m²/year

All inputs not changed in a row use: Annual site electricity = 12,000 kWh/year; Floor area = 100 m². These are chosen examples, not current rates or product performance claims.

Common questions

How do I calculate electricity use per square metre?

Divide annual electricity kWh by the corresponding floor area in m².

Is this a building efficiency rating?

No. It is an arithmetic intensity that needs context such as building use, occupancy and weather.

Does this include gas energy?

No. This page is explicitly electricity-only. A whole-building EUI needs all relevant energy on a compatible basis.

Can I calculate an energy cost index?

Divide a consistently defined annual cost by area separately. A kWh intensity alone is not a money metric.

Why show kBtu per square foot?

It expresses the same supplied electricity energy intensity in another convention, using IT Btu and exact area scaling.

Which inputs should I verify before using this result?

Check the units, dates and measurement boundary shown above. The examples are deliberately chosen scenarios rather than current tariffs, certified product ratings or promises about a particular installation.

Where do the formulas and example values come from?

The method is explained on this page and the published references are listed below as plain-text addresses. Example inputs are illustrative; comparison rows are computed with the same calculation function as the form.

Formula sources and references

These references support the units and underlying methods. Defaults and comparison cases are illustrative inputs, not current tariffs or product test data.

  • NIST SP 811, Appendix B: SI and non-SI conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors
  • NIST SP 811 footnotes: International Table Btu and therm conventionshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-footnotes
  • US EIA: Measuring electricity; power and energy unitshttps://www.eia.gov/energyexplained/electricity/measuring-electricity.php