Electricity Costby Voltage Drop Calculator

Electricity calculators / Appliances & equipment

Know your usage. Understand your bill.

Motor Power Consumption Calculator

A motor nameplate horsepower rating describes mechanical output at rated conditions. Purchased electrical power is higher because of motor losses. Load fraction scales the shaft requirement, while efficiency converts shaft output into electrical input. Efficiency at full load may not represent an intermittently operated or lightly loaded machine.

Your inputs

mechanical hp
%
%
h/day
days
currency/kWh

Example inputs are editable. Use your own equipment data and current tariff. Prices use one consistent currency: enter 20 cents or pence as 0.20.

Your result

Awaiting your inputs

Enter your values and press Calculate. Your result will appear here.

Clear units · Editable assumptions · Published formula sources

The method

Formula and calculation steps

Electrical input kW = mechanical hp×0.745699872×load fraction/efficiency; kWh = input kW×hours.

Estimate motor-driven pump, fan or machine electricity use from shaft horsepower, loading and efficiency.

  1. Identify the quantities and units required by the form.
  2. Use measurements, a current bill or relevant equipment data for the same period.
  3. Apply the displayed formula, then check the assumptions and related outputs.

This uses mechanical horsepower. Input efficiency must apply at the chosen load. It does not determine startup current, thermal suitability or actual part-load performance.

Motor horsepower, pump consumption and electrical input

A motor nameplate horsepower rating describes mechanical output at rated conditions. Purchased electrical power is higher because of motor losses. Load fraction scales the shaft requirement, while efficiency converts shaft output into electrical input. Efficiency at full load may not represent an intermittently operated or lightly loaded machine.

A water pump, agitator, lift or fan power consumption estimate can use this model if the required shaft load is known. It does not infer that load from flow, head, elevator duty or process conditions. A pool pump may run at several speeds; calculate each speed with its own electrical input or use representative measured kWh.

Check the numbers

Motor Power Consumption Calculator: calculated examples

Compare stated scenarios rather than an unexplained rule of thumb. Each row uses the same calculation function as the form.

Worked example with the starting inputs

Rated shaft power: 5 mechanical hp; Fraction of rated shaft load: 75 %; Motor efficiency at this load: 88 %; Operating hours per day: 4 h/day; Days in period: 30 days; Electricity unit rate: 0.2 currency/kWh. Motor electricity cost: 76.26476 currency.

OutputComputed value
Motor electricity cost76.26476 currency
Real electrical input3.177698 kW
Period energy381.323798 kWh
Loaded shaft output2.796375 kW

How the answer changes

ScenarioChanged inputResult
1.25 mechanical hpRated shaft power: 1.25 mechanical hp19.06619 currency
2.5 mechanical hpRated shaft power: 2.5 mechanical hp38.13238 currency
3.75 mechanical hpRated shaft power: 3.75 mechanical hp57.19857 currency
5 mechanical hpRated shaft power: 5 mechanical hp76.26476 currency
7.5 mechanical hpRated shaft power: 7.5 mechanical hp114.397139 currency
10 mechanical hpRated shaft power: 10 mechanical hp152.529519 currency
15 mechanical hpRated shaft power: 15 mechanical hp228.794279 currency

All inputs not changed in a row use: Rated shaft power = 5 mechanical hp; Fraction of rated shaft load = 75 %; Motor efficiency at this load = 88 %; Operating hours per day = 4 h/day; Days in period = 30 days; Electricity unit rate = 0.2 currency/kWh. These are chosen examples, not current rates or product performance claims.

Common questions

How do I calculate kWh using hp?

Convert the loaded shaft horsepower to kW, divide by efficiency, then multiply by operating hours. Horsepower alone cannot specify energy.

Does a 1 hp motor draw 746 W?

About 746 W is one mechanical horsepower of shaft output. Electrical input is higher when efficiency is below 100%.

Can I calculate pump power consumption?

Yes, if you know shaft horsepower, load and motor efficiency. This is not a hydraulic sizing model and does not determine required head or flow.

Do I multiply by power factor as well?

Not when starting from real shaft power and efficiency. Power factor is needed when estimating real AC input from voltage and current.

Can this calculate variable-speed savings automatically?

No. Use measured or validated operating points. Motor, drive and system behavior change with speed and load.

Which inputs should I verify before using this result?

Check the units, dates and measurement boundary shown above. The examples are deliberately chosen scenarios rather than current tariffs, certified product ratings or promises about a particular installation.

Where do the formulas and example values come from?

The method is explained on this page and the published references are listed below as plain-text addresses. Example inputs are illustrative; comparison rows are computed with the same calculation function as the form.

Formula sources and references

These references support the units and underlying methods. Defaults and comparison cases are illustrative inputs, not current tariffs or product test data.

  • US Department of Energy: Determining Electric Motor Load and Efficiencyhttps://www.energy.gov/sites/prod/files/2014/04/f15/10097517.pdf
  • NIST SP 811, Appendix B: SI and non-SI conversion factorshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors
  • Virginia Cooperative Extension, publication 2901-9014: appliance energy estimationhttps://www.pubs.ext.vt.edu/2901/2901-9014/2901-9014.html